Reinforced Cement Concrete Design
Contents |
Concrete:
Concrete is a stone like substance obtained by permitting a carefully proportioned mixture of cement, sand and gravel or other aggregate and water to harden in forms of the shape and of dimensions of the desired structure.Reinforced cement concrete:
Since concrete is a brittle material and is strong in compression. It is weak in tension, so steel is used inside concrete for strengthening and reinforcing the tensile strength of concrete. The steel must have appropriate deformations to provide strong bonds and interlocking of both materials. When completely surrounded by the hardened concrete mass it forms an integral part of the two materials, known as "Reinforced Concrete".
Advantages and disadvantages of reinforced concrete
Flexural Strength of Concrete
Reinforced Concrete is a structural material, is widely used in many types of structures. It is competitive with steel if economically designed and executed.
Advantages of reinforced concrete
|
Related Pages |
Disadvantages of reinforced concrete
-
It needs mixing, casting and curing, all of which affect the final strength of concrete
-
The cost of the forms used to cast concrete is relatively high
-
It has low compressive strength as compared to steel (the
ratio is about 1:10 depending on material) which leads to large sections
in columns/beams of multistory buildings
Cracks develop in concrete due to shrinkage and the application
of live loads
Factors affecting the joint performance of steel and Concrete
Reinforced cement concrete Design philosophy and concepts
The design of a structure may be regarded as the process of selecting proper materials and proportioned elements of the structure, according to the art, engineering science and technology. In order to fulfill its purpose, the structure must meet its conditions of safety, serviceability, economy and functionality.
Serviceability: No excessive deflection, no excessive deformation and no cracking or vibrations No excessive reinforcement. Must be able to perform the function, it is built for. |
It is based on the ultimate strength of the structural members assuming a failure condition, whether due to the crushing of concrete or due to the yield of reinforced steel bars. Although there is additional strength in the bar after yielding (due to Strain Hardening), this additional strength in the bar is not considered in the analysis or design of the reinforced concrete members. In the strength design method, actual loads or working loads are multiplied by load factor to obtain the ultimate design loads. The load factor represents a high percentage of factor for safety required in the design. The ACI code emphasizes this method of design.Strength design method
This design concept is based on elastic theory, assuming a straight line stress distribution along the depth of the concrete. The actual loads or working loads acting on the structure are estimated and members are proportioned on the basis of certain allowable stresses in concrete and steel. The allowable stresses are fractions of the crushing strength of concrete (fc') and the yield strength (fy). Because of the differences in realism and reliability over the past several decades, the strength design method has displaced the older stress design method.Working stress design
It is a further step in the strength design method. It indicates the state of the member in which it ceases to meet the service requirements, such as, loosing its ability to withstand external loads or local damage. According to limit state design, reinforced concrete members have to be analyzed with regard to three limit states:Limit state design
- Load carrying capacity (involves safety, stability and durability)
- Deformation (deflection, vibrations, and impact)
- The formation of cracks
Fundamental assumptions for Reinforced Concrete's Behavior
Reinforced concrete's sections are heterogeneous, because they are made up of two different materials - steel and concrete. Therefore, proportioning structural members by ultimate stress design is based on the following assumptions:
-
Strain in concrete is the same as in reinforcing bars at the
same level, provided that the bond between the concrete and steel is
adequate
-
Strain in concrete is linearly proportional to the distance from the neutral axis.
-
Modulus of elasticity for all grades of steel is taken as Es =
29 x 10 ^ 6 psi. The stress in the elastic range is equal to the strain
multiplied by Es.
-
Plane cross sections continue to be plane after bending.
- Tensile strength of concrete is neglected because:
- Concrete's tensile strength is about 1/10 of its compressive strength.
- Cracked concrete is assumed to be not effective Before cracking, the entire cross section is effective in resisting the external moments.
- The method of elastic analysis, assuming an ideal behavior at all levels of stress is not valid. At high stresses, non-elastic behavior is assumed, which is in close agreement with the actual behavior of concrete and steel.
- At ultimate strength, the maximum strain at the extreme compression fibers is assumed to be equal to 0.003 by the ACI code provisions. At the ultimate strength, the shape of the compressive stress distribution may be assumed to be rectangular, parabolic or trapezoidal.
Loads
Structural members must be designed to support specific loads. Loads are those forces for which a structure should be proportioned. Loads that act on structure can be divided into three categories.
- Dead loads
- Live loads
- Environmental loads
Dead loads are those that are constant in magnitude and fixed in location throughout the lifetime of the structure. It includes the weight of the structure and any permanent material placed on the structure, such as roofing, tiles, walls etc. They can be determined with a high degree of accuracy from the dimensions of the elements and the unit weight of the material.Dead Loads:
Live loads are those that may vary in magnitude and may also change in location. Live loads consists chiefly occupancy loads in buildings and traffic loads in bridges. Live loads at any given time are uncertain, both in magnitude and distribution.Live loads:
Consists mainly of snow loads, wind pressure and suction, earthquake loads (i.e inertial forces) caused by earthquake motions. Soil pressure on subsurface portion of structures, loads from possible ponding of rainwater on flat surfaces and forces caused by temperature differences. Like live loads, environmental loads at any given time are uncertain both in magnitude and distribution.Environmental loads:
ACI Code Safety Provisions
Structural members must always be proportioned to
resist loads greater than service or actual loads, in order to provide
proper safety against failure. In the stenght design method, the member
is designed to resist the factored loads which are obtained by
multiplying the factored loads with live loads.
Different factors are used for different loadings. As
dead loads can be estimated quite accurately, their load factors are
smaller than those of live loads, which have a high degree of
uncertainity. Several load factor conditions must be considered in the
design to compute the maximum and minimum design forces. Reduction
factors are used for some combinations of loads to reflect the low
probability of their simultaneous occurrences. Now if the ultimate load
is denoted by U, the according to the ACI code, the ultimate required strength U, shall be the most critical of the following
Basic Equation U = 1.2D + 1.6L
In addition to the load factors, the ACI code
specifies another factor to allow an additional reserve in the capacity
of the structural member. The nominal strength is generally calculated
using accepted, analytical procedures based on statistics and
equilibrium. However, in order to account for the degree of accuracy
within which the nominal strength can be calculated and for adverse
variations in materials and dimensions, a strength reduction factor (Ø)
should be used in the strength design method. Values of the strength
reduction factor Ø (Phi) are:
For flexure of tension controlled sections Ø = 0.9
For shear and torsion Ø = 0.75
For compression members with spiral reinforcement Ø = 0.70
For compression members with laterla ties Ø = 0.65
Nominal strength
Actual strength from the material properties is called the nominal strength.
Nominal x Ø = Design strength
As safe design is achieved when the structural
strength obtained by multiplying the nominal strength by the reduction
factor Ø, exceeds or equals the strength needed to withstand the
factored loads.
Design process is the reverse of loading. Design starts from the foundation, unlike the load which transfers to the foundation only at the end. |
where
Mu, Vu and Pu equals external factored moments, shear forces and axial forces.
Mn, Vn and Pn equals the nominal moment, shear and axial capacity of the member respectively
Strucural Concrete elements
Slab:
Slabs are horizontal slab elements in building floors
and roof. They may carry gravity loads as well as lateral loads. The
depth of the slab is usually very small relatively to its length and
width.
Beams:
Long horizontal or inclined members with limited
width and height are called beams. Their main function is to transfer
loads from the slab to the columns.
Column:
Columns are vertical members that support loads from the beam or slabs. They may be subjected to axial loads or moments.
Frames:
Frames are structural members that consists of combination of slab, beams and columns
Footings:
Footings are pads or strips that support columns and spread their load directly to the soil.
Walls:
Walls are vertical plate elements resisting gravity as well as lateral loads e.g retaining walls, basement walls. etc
Codes of Practice
Code is a set of technical specifications and
standards that control important details of design and construction. The
purpose of code is to produce sound structures so that the public will
be protected from poor and inadequate design and construction.
Maximum reinforcement ratios for singly reinforced beams
ACI code limits the amount of reinforcement in terms of a minimum net tensile strain of = 0.005
Frther the ACI code defines a tension controlled
member as one with a net tensile strain greater than or equal to 0.005.
The coresponding strength reduction factor is Ø = 0.9. For compression
controlled members as having a net tensile strain of less than 0.002.
The strength reduction factor for compression controlled members is
0.65. A value of 0.70 may be used if members are spirally reinforced and
ACI code allows a linear interpolation of Ø based on as shown.
0.005 => Ø = 0.9
0.002 ==> Ø = 0.65
Graph of Net tensile strain
Minimum reinforcement ratio (ρmin)
If the external moment applied on the beam is very
small and the dimensions of sections are specified (as is sometimes
required architecturally) and are large than needed to resist the
external ultimate moment, the calculations may show that very small or
no steel reinforcement is required. In this case the maximum tensile
stress due to bending moment may be equal to or less than the modulus of
rupture of concrete.
If no rinforcement is provided, sudden failure
will be expected when the first crack occurs, thus giving no warning.
ACI code specifies a minimum steel area.
Design procedure for double reinforced beams
Step # 1:
Find the strength Mu of a singly reinforced beam
/section using the already established 'b' and 'd' i.e. the dimensions
of the section and with > ρ = ρmax (OR) ρ for = 0.005 to ensure that Ø = 0.90
Mu = Ø As fy (d - a/2)
a = As fy / 0.85 fc' b
If Mu required > Md of simply reinforced beam . Proceed with doubly reinforced beam design.
Step # 2:
Find excess moment i.e
Mu1 = Mu - Mu2
and determine the resulting compression steel area As1 = As and rentaively assume that fs = fy, then
As' = Mu1 /Ø fy (d - d' )
Step# 3:
Find the total tensile stel area i.e
As = As' + As2
Step # 4:
Check whether the compression steel is yielding or
not and use the corresponding stress in the steel for calculating the
forces and moments. If compression steel is less than fy, then the compression steel area is to be revised ==> As' fs' < As' fy ==> increase As rev.
The revised compression steel area acting at fs must provide the same force as the trial steel area that was assumed to act at fy.
So
C = T1
A's rev f 's= As trial fy
A's rev = As trial fy / fs'
Tensile steel area need not to be revised because it acts at fy, as assumed.
Step # 5:
Check for satisfactory minimum and maximum reinforcement ratios
Step # 6:
Select appropriate bar size and draw the sketches.
thanks for a good information...foam generator
ReplyDelete